I take it you are replacing the gas stove with an electric stove? The new stove will have a nameplate with the amperage required. A 40 amp 220 volt is typical. This would use an 8/3 wire and a 40 amp 2 pole breaker. You would also want a range plug and box, as well … Read more
Norm Grande
Norm Grande answered
If there is room in your electrical panel, a new circuit breaker or two can be added so that your addition has its own circuits. A wire is run from the electrical panel to your new area, and then used to wire the new plugs and lights.
Norm Grande
Norm Grande answered question
It is preferred (safety) to install the switch on the hot side (narrow prong) of the line, otherwise there is a shock hazard when changing bulbs. If you have already installed the switch on the wrong line, you can reverse the plug on the end and change wires on bulb socket??
Norm Grande
Norm Grande answered question
You need to check with the Electrical Inspector, or a local electrician, as it varies from state to state, etc. I moved from an area where the ground went from the ground rod to the panel neutral, and ground. Where I now live, the Electrical utility wants it on the neutral at the meter base, … Read more
Norm Grande
Norm Grande answered question
This one is easy, if you stay methodical. I use a process of elimination as I wire. First, connect all the grounds together and wire nut them. Next, connect all the white wires together, except the white wire from the 3-way (C) and wire nut them. Now for the good stuff, take the black from … Read more